HWg-WLD: Water leak detector

HWg_WLD_water leak detectorHWg-WLD is a network-enabled water leak detector with a water-absorbing sensing cable. HWg-WLD features a built-in web server, SNMP support, and e-mail alert to water flooding. HWg-WLD can remotely control a relay output over the network (a relay is switched when a water leak is detected along the sensing cable).

HWg-WLD detects water leaks or water floods along the entire length of the sensing cable. The sensing cable detects even the smallest volume of water, ethylene glycol, or other conductive liquid. HWg-WLD can be ordered in two versions depending on the supply of power (power adapter or PoE IEEE 802.3af). The sensing cable detects as little as a few drops of the liquid, and can be used to detect condensation. After flooding, the cable can be dried and reused.
HWg-WLD features a built-in web server and SNMP support. In case of an alarm, the device sends an e-mail or SNMP trap. Alarms can be also signaled by switching a remote relay over the Ethernet. When a leak is detected, HWg-WLD activates a relay of a remote Poseidon or Damocles unit (Box-2-Box mode).


Applications:
  • Detection of water leaking from pipes (cable runs along the pipes)
  • Detection cable laid along the walls
  • Under raised floors
  • Above suspended ceilings
  • Detection of water leaks in drip trays
  • Detection of water leaks under A/C outlets

LINKS


Tuesday, June 1, 2010

Damocles 1208: I/O over Ethernet

Damocles 1208Damocles 1208 is a device with 12 remote inputs and 8 outputs over Ethernet with Web interface. The device provides M2M communication for connection to SNMP and SCADA systems. Damocles 1208 has pulse counters on digital inputs. The device supports E-mail and SNMP trap notifications of input state changes. Box-2-Box mode - outputs can be controlled over the LAN by another device.

Damocles 1208 provides digital inputs (DI) and digital outputs (DO) that can be remotely controlled over the Web. The Inputs and outputs can also be controlled over the network using M2M protocols (SNMP, Modbus/TCP, XML over HTTP. Typical application of Damocles 1208 involves energy consumption monitoring by counting pulses from meters. The HWg-PDMS application converts pulses to kWh per time period and creates MS Excel output reports.


Applications:
  • Remote equipment monitoring:Monitoring of A/C, UPS, security system status (status relays)
  • Energy consumption monitoring:Counting of pulses from electricity / water / gas meters. Conversion to price using HWg-PDMS in MS Excel.
  • Alarm alerts:Turning on a warning light or a horn upon alarm at another unit (over the network, Box-2-Box mode)
  • UPS and back-up generator monitoring:Fuel level, diesel generator status, remote start over IP
  • Security systems:IP surveillance systems (external sensors) and Equipment status, access control systems
  • SCADA:Connection of external inputs to multiple independent systems

LINKS


Wednesday, May 12, 2010

HWg-PWR – Ethernet energy meter

HWg-PWRHWg-PWR is an Ethernet-enabled device for remote monitoring and metering of electricity, heat, water or gas consumption using electricity meters, water meters, gas meters, heat meters and other sensors equipped with the M-BUS interface. In addition to metering, the device also supports alarming through e-mail or SNMP traps whenever allowed values are exceeded.

M-BUS is a standard in energy metering. As opposed to pulse counters, it works with absolute values (acquired data can be used as an argument against the utility bill), and at the same time allows working with additional quantities, such as voltage, current, flow, drift, etc.

HWg-PWR Ethernet energy meter


Applications:
  • Total electricity consumption
  • Instantaneous electricity consumption
  • Instantaneous voltages at individual lines
  • Instantaneous current flowing through each line
  • Power factor (cos ϕ) of individual lines

LINKS


Wednesday, April 7, 2010

IP WatchDog HWg-WR02a: Ping restarter

IP WatchDog HWg-WR02aIP WatchDog HWg-WR02a monitors the functionality of a device over IP (PING/WEB) or serial line (RS-232), automatically restarts it upon failure. The device can monitor two devices (two independent channels, two 110/230VAC relays). Industrial applications benefit from DIN rail compatibility.

IP WatchDog WR02a (ping restarter) periodically monitors the functionality of a device by transmitting or receiving a specified “I'm alive and OK” signal over IP or RS-232. If the correct reply is not received in time, the device is restarted with a relay. Failures are detected with five distinct methods, separately for each channel (Ping Tx/Rx, Web page request/push, RS-232 data). Web WatchDog WR02a allows flexible configuration – method of functionality detection, switchoff time when restarting.


Applications:
  • Operation monitoring / IP restart: servers / routers; IP video cameras; WiFi links / access points; industrial systems
  • Connectivity monitoring: activation of a back-up link; detection of connectivity outage (relay >> horn); monitoring of ADSL and cable modems; security and access control systems

LINKS


Tuesday, March 16, 2010

HWg-STE PoE: SNMP thermometer

HWg-STE PoEHWg-STE PoE is IP enabled web thermometer with Email alerts and SNMP. The device measures temperature and humidity with two external probes. HWg-STE PoE can be powered over Ethernet or from wall plug adaptor. Windows graphs and MS Excel reporting software are included. It´s delivered with one temperature probe, power adaptor and software.

The HWg-STE PoE web thermometer is configured using a built-in web server. If the temperature (humidity) exceeds a specified threshold, an e-mail alert is sent. The HWg-STE IP thermometer is fully SNMP compatible. HWg-STE power over ethernet thermometer is easy to install.

HWg-STE PoE IP thermometer hygrometer


Applications:
  • Remote rack monitoring: Temperature / humidity monitoring inside and outside of a rack (cabinet), SNMP monitoring, PoE (Power over Ethernet - IEEE 802.3af).
  • Air conditioning failure: Temperature monitoring; rising temperature indicates cooling fault.
  • Heating system monitoring:Remote monitoring of a heating system, alert by e-mail or SMS (Email-2-SMS) to a danger of freezing.
  • Cooler/freezer monitoring:Sends an e-mail if the cooler malfunctions. Logs operating and storage conditions. Temperature reports.
  • Heating optimization:Web PoE thermometer saves heating and air-conditioning costs. Temperature reports for MS Excel.

  • Food storage
    :Monitors optimal storage conditions. With application software, HACCP reports can be created.

LINKS


Tuesday, October 13, 2009

Poseidon 4002: Rack mount environment monitoring

Posedion 4002Posedion 4002 is a 19" 1U rack mount system for datacenter temperature and environment monitoring. The Poseidon solution monitors racks and computer rooms (temperature, humidity, electricity supply, access to the room, detectors). Alerting works by e-mail, SNMP traps, SMS, output relays.


  • Ethernet: RJ45 (10BASE-T)
  • WEB: Embedded WEB server / GUI
  • Sensors: 4xRJ11 1-Wire UNI (max 12 sensors)
  • Inputs: 6 dry contact inputs (for detectors)
  • Outputs: 2 output relays (24 VDC)
  • M2M communication protocols: SNMP, XML and Modbus/TCP
  • Physical features: 10" or 19" rack mount, dimensions: 184 x 44 x 125 [mm] (1U)
  • Response to thresholds: SNMP trap, E-mail, SMS
  • Built-in functions: Output controlled with an input or sensor value ("Thermostat" mode).
  • Support for programmers: HWg SDK
  • Supported software (HWg-PD Trigger, HWg-PDMS)


rack mount environment monitoring


Applications:
  • Data centers: Rack mount environment monitoring, Remote rack monitoring, Computer room temperature, SNMP environment monitori ng system

  • Air-conditioning monitoring: A/C operation and water leak detection, Computer room temperature, Humidity in the datacenter (inside racks, in the A/C outlet, under the raised floor), Rack mount temperature monitoring system

  • UPS / back-up generator monitoring:Fuel level, diesel generator status, remote start over IP, monitoring of temperature and service contacts

  • Security systems:IP surveillance systems (external sensors), Equipment status, access control systems

LINKS


Tuesday, September 29, 2009

HWg-PDMS: Monitoring software

HWg-PDMSHWg PDMS is a Windows application, primarily designed for IT environments, that logs temperature, energy consumption, or access to monitored rooms. Up to 100 input devices can be connected over a network. The application can display a graphical summary and generate MS Excel reports.


  • Registered version is free of charge for one year
  • Data are collected over a LAN (via http and the device IP address / via an e-mail account)
  • Data collection runs in the background as a Windows service
  • Simple export to MS Excel (runs periodically in the background



Typical HWg-PDMS users
  • IT department: Software for monitoring temperature, power supply, and access to the server room

  • Audit: End user that needs data logging (operations / storage audit)

  • Outsourcing: Record of the quality of the provided services. The generated MS Excel summary can be attached to the invoice as a quality assurance measure.

  • Operations logs: Maintaining a history record that can be manually exported to MS Excel if needed.